Details
NRND

RE-max 13 Ø13 mm, Precious Metal Brushes, 0.75 Watt, with cables

Part number 268340

RE-max 13 Ø13 mm, Precious Metal Brushes, 0.75 Watt, with cables
Price scales Quantity Price per unit
Prices excluding VAT and shipping costs 1-4 $95.13
5-19 $86.75
20-49 $79.50
from 50 On request

NRND (Not Recommended for New Designs): These products continue to be available, but are not recommended for new projects. Our sales team will be happy to suggest alternatives.

Specifications

Technical illustrations

Information: Drawings are not to scale.

Values at nominal voltage
Nominal voltage 1.5 V
No load speed 7010 rpm
No load current 32.6 mA
Nominal speed 2960 rpm
Nominal torque (max. continuous torque) 0.892 mNm
Nominal current (max. continuous current) 0.48 A
Stall torque 1.54 mNm
Stall current 0.786 A
Max. efficiency 64 %
Characteristics
Terminal resistance 1.91 Ω
Terminal inductance 0.0333 mH
Torque constant 1.96 mNm/A
Speed constant 4870 rpm/V
Speed / torque gradient 4740 rpm/mNm
Mechanical time constant 14.6 ms
Rotor inertia 0.293 gcm²
Thermal data
Thermal resistance housing-ambient 47.5 K/W
Thermal resistance winding-housing 14 K/W
Thermal time constant winding 4.8 s
Thermal time constant motor 186 s
Ambient temperature -20...+65 °C
Max. winding temperature +85 °C
Mechanical data
Bearing type sleeve bearing
Max. speed 11000 rpm
Axial play 0.05 - 0.15 mm
Radial play 0.014 mm
Max. axial load (dynamic) 0.8 N
Max. force for press fits (static) 35 N
(static, shaft supported) 240 N
Max. radial load 1.4 N, 5 mm from flange
Other specifications
Number of pole pairs 1
Number of commutator segments 7
Number of autoclave cycles 0
Product
Weight 15 g
  • Operating Range

    Continuous operation range
   
     
    Short term operation range
   

Description

maxon DC motors are high-quality motors equipped with powerful permanent magnets. The centerpiece of the motor is the globally patented ironless rotor. Our precious metal brushed combination ensures a high level of consistency of the low contact resistance, even after a long standstill. The motors operate with small startup voltages and extremely low levels of electrical interference.